Model ComfoAir 70 ComfoSpot 50
Type of system   Retrofit MVHR with supply and extract ducting De-central retrofit MVHR
Recomm. max. floor area [m2] 37 m2 37 m2
Max. air flow @100Pa [m3/h] 65/ 18 l/s 55/ 15 l/s
Min. air flow [m3/h] 15/ 4 l/s 15/ 4 l/s
Recommended air flow [m3/h] 20-40/ 5.6-11 l/s 15-25/ 4-7 l/s
Orientation wall, spigots back or side wall
Performance  
Heat Recovery (Passive H) % 85% 80%
Heat Recovery (SAP) % X X
Humidity Recovery % 64% 54%
Specific Electric Power (PH) [Wh/m3] 0.24 0.3
SFP (SAP) [W/l/s} N/A N/A
SAP Kitchen + max. wet rms N/A N/A
Noise ***/ ***** ****
Breakout noise @3m @60% [dB(A)] 27.3 17.1
Breakout noise @3m 60m3/h [dB(A)] 36.4 / two ducts: 22.7 23.3
Breakout noise @3m 90m3/h [dB(A)] X X
Breakout noise @3m 120m3/h [dB(A)] X X
Breakout noise @3m 150m3/h [dB(A)] X X
Breakout noise @3m 180m3/h [dB(A)] X X
Breakout noise @3m 210m3/h [dB(A)] X X
Breakout noise @3m 240m3/h [dB(A)] X X
Breakout noise @3m 270m3/h [dB(A)] X X
Technical  
Spigot Size [mm] 100 internal N/A
Weight [kg] 14 5
Materials internal EPP/ Alu EPP/ ABS
Type of heat exchanger ERV ERV
Condensate connection [mm] None None
Filter grade (*optional) M5/ F7* M5/ F7*
Frost protection [°C] inherent to -8 inherent to -8
Peak winter performance Yes Yes
Max power pre-heater* [W] X X
Max. power cons. w/o pre-h. [W] 17 15
Motors, volume flow constant EC EC
Summer bypass [100%] Yes Yes
Controls   in-built controller in-built controller
Type of controller X X
App control/ monitoring X X
Boost activation Auto Auto
Humidity sensor Integrated* Integrated*
CO2 sensor Integrated* Integrated*
BMS capability No No
Fire alarm integration indirect w. relay indirect w. relay
Fault indicator No No
Heating & cooling options   X X
Cooling module X X
Max. cooling output [W] X X
Max. heat output [W] X X
Integrated controls X X
Refrigerant X X
Hot water tank X X
Servicability Made in D/ NL D/ NL
All parts replaceable Yes Yes
Fan bearings exchangeable
Warranty – free of charge [years] 2 2
Warranty – extended [years] 4 (through us) 4 (through us)

Dimensions of the ComfoSpot 50

The ComfoSpot 50 needs a ~340mm core through an external wall with a minimum depth of 335mm up to 600mm. Extension pieces are available.

Compared to the ComfoAir 70, the ComfoSpot 50 is a quieter de-central solution when no ducting is to be connected. If ducting can be connected, then the ComfoAir 70 is a quieter solution.

ComfoSpot 50
ComfoAir 70

Dimensions of the ComfoAir 70

The ComfoAir 70 needs a ~270mm core through an external wall with a minimum depth of 275mm up to 600mm. Extension pieces are available.

Compared to the ComfoSpot 50, the ComfoAir 70 is a quieter solution when ducting can be connected.

CA70 Duct Connections

The ComfoAir 70 has 100mm duct connections on its side and back.

  • Ports for supply on the right hand side and back of the unit (seen from the front).
  • Ports for extract on the left hand side and back of the unit.

Only one supply and one extract room can be connected to the MVHR unit.

The EPP end cap on the back can be taken out and inserted into the side port, when ducting is connected to it.

Possible ducts that can be connected:

  • 100mm round PVC or metal ducting
  • 90mm semi-rigid ducting

ComfoAir 70

Installation of the ComfoSpot 50

Please see below for a brief summary how to install the ComfoSpot

Zehnder ComfoSpot 50 – Installation and functions

Installation of the ComfoAir 70

Zehnder ComfoAir 70 – Mounting instructions

Webinar Decentral MVHR

Zehnder Webinar: Decentralised ventilation units

Further Information

Latest News

Dandashill Platform 3 Passive House Development

Passivhaus deemed to satisfy UK NZCBS

Passivhaus deemed to satisfy UK NZCBS The Passivhaus standard is now deemed to satisfy certain aspects of the UK Net Zero Carbon Buildings Standard (UK…

Glasgow Homebuilding & Renovation Show

Scottish Homebuilding & Renovating Show

Scottish Homebuilding & Renovating Show Glasgow PAUL Heat Recovery is exhibiting at the SEC in Glasgow on the 9th and 10th May 2026. Please visit…

Big Magic training

Big Magic Installer Training

Big Magic Installer Training May 2026 PAUL Heat Recovery hosts a product training event for the Big Magic MVHR system on Thursday 7th May 2026…

Launch of Zehnder Academy

Launch of the UK Zehnder Academy

Launch of the UK Zehnder Academy As Approved Zehnder Partner we were invited for the official launch of the UK Zehnder Academy in Camberley on…

ComfoSpot/ CA70 - General Info

CS50 CA70

Maintenance of ComfoSpot 50 and CA70

CS50 CA70

Warranty Information

installation partners

Comparison of Recommended MVHRs

passive house MVHR